TT PE HP Pipes with STD joint DN80-600


PRODUCT FAMILY
- PIPES
- SOCKETTED PIPES
MARKET / APPLICATION
- Water
COATING
- Ext - Polyethylene coating / High corrosive soils
- Int - Cement mortar
RANGE / MARK ®
- ® TT PE Download the file
CHOICE OF PRODUCT
- Socket Pipes STANDARD
ID
- ENATE65STD517
Short title
- TT PE HP Pipes with STD joint
Date
- 30/11/-0001
DN
- 80 - 600
Main features
TT PE HP Pipes with STD joint DN80-600![]() | STD joint for TT PE HP Pipes DN8... | STD Vi joint for TT PE HP Pipes ... | ||
DN | Lu | Reference | PFA | PFA |
mm | m | bar | bar | |
80 | 6.000 | SSA80C60AG SSA80C60AG | - | - |
100 | 6.000 | SSB10C60AG SSB10C60AG | - | - |
125 | 6.000 | SSB12C60AG SSB12C60AG | - | - |
150 | 6.000 | SSB15C60AG SSB15C60AG | - | - |
200 | 6.000 | SSB20D60AG SSB20D60AG | - | - |
250 | 6.000 | SSB25D60AG SSB25D60AG | - | - |
300 | 6.000 | SSB30D60AG SSB30D60AG | - | - |
350 | 6.000 | SSB35F60AG SSB35F60AG | - | - |
400 | 6.000 | SSB40F60AG SSB40F60AG | - | - |
450 | 6.000 | SSB45F60AG SSB45F60AG | - | - |
500 | 6.000 | SSB50F60AG SSB50F60AG | - | - |
600 | 6.000 | SSB60F60AG SSB60F60AG | - | - |
TT PE HP Pipes with STD joint DN80-600 | STD joint for TT PE HP Pipes DN8... | STD Vi joint for TT PE HP Pipes ... | ||||||||||
DN | Lu | Class | e | e1 | Ø DE | Ø DI | P | Ø B | Mass | Reference | PFA | PFA |
mm | m | mm | mm | mm | mm | mm | mm | kg/m | bar | bar | ||
80 | 6.000 | C64 | 5.4 | 1.8 | 98 | 101.4 | 92.5 | 147.0 | 14.500 | SSA80C60AG SSA80C60AG | - | - |
100 | 6.000 | C64 | 5.4 | 1.8 | 118 | 121.4 | 94.5 | 168.0 | 17.700 | SSB10C60AG SSB10C60AG | - | - |
125 | 6.000 | C64 | 5.4 | 2.0 | 144 | 147.4 | 97.5 | 195.0 | 22.000 | SSB12C60AG SSB12C60AG | - | - |
150 | 6.000 | C64 | 5.5 | 2.0 | 170 | 173.4 | 100.5 | 222.0 | 26.500 | SSB15C60AG SSB15C60AG | - | - |
200 | 6.000 | C50 | 5.4 | 2.0 | 222 | 225.2 | 106.5 | 279.0 | 34.700 | SSB20D60AG SSB20D60AG | - | - |
250 | 6.000 | C50 | 6.4 | 2.0 | 274 | 276.8 | 105.5 | 352.0 | 48.900 | SSB25D60AG SSB25D60AG | - | - |
300 | 6.000 | C50 | 7.4 | 2.2 | 326 | 328.8 | 107.5 | 392.0 | 65.700 | SSB30D60AG SSB30D60AG | - | - |
350 | 6.000 | C40 | 7.1 | 2.2 | 378 | 380.9 | 110.5 | 446.0 | 78.800 | SSB35F60AG SSB35F60AG | - | - |
400 | 6.000 | C40 | 7.8 | 2.2 | 429 | 431.9 | 112.5 | 499.5 | 95.300 | SSB40F60AG SSB40F60AG | - | - |
450 | 6.000 | C40 | 8.6 | 2.2 | 480 | 483.0 | 115.5 | 554.0 | 115.100 | SSB45F60AG SSB45F60AG | - | - |
500 | 6.000 | C40 | 9.3 | 2.5 | 532 | 535.0 | 117.5 | 608.6 | 137.500 | SSB50F60AG SSB50F60AG | - | - |
600 | 6.000 | C40 | 10.9 | 2.5 | 635 | 638.1 | 132.5 | 718.0 | 185.200 | SSB60F60AG SSB60F60AG | - | - |
![]() |
Legend:
- DN: nominal diameter
- Lu: laying length, in m
- Class: pressure class according to EN 545 and ISO 2531
- e: nominal thickness according to ISO 2531, in mm
- e1: thickness of polyethylene according to EN 14628-1
- ØDE: external nominal diameter of the barrel according to EN 545 and ISO 2531, in mm
- ØDI: internal nominal diameter of the socket, in mm
- P: nominal depth of the socket, in mm
- ØB: nominal diameter of the socket, in mm
- Mass: total mass per meter (including cement coating and socket), determined with the nominal thickness, in kg/m
- Reference: commercial reference Saint-Gobain PAM
- Marking sticker can be different depending on DN
Field of use:
- Soils characteristics: Ductile iron pipes coated with TT PE may be buried in contact with a large number of soils, normal and highly corrosive soils (low resistivity soil, mixed soils, polluted soils...), also in soils with occurrence of stray currents. Please refer to the informative annex E of EN545.
- Water characteristics: Ductile iron pipelines supplied with lining sulfate resisting blast furnace cement mortar may be used to convey all types of water intended for human consumption in conformity with the Directive 98/83/EC. For other types of water, the limits of use are as given in below Table. Please refer to the informative annex D of EN545. Minimum value Maximum value Parameter pH CO2 aggressive Sulphate Magnesium Ammonium Unit - mg/l mg/l mg/l mg/l Value 5,5 15 3000 500 30
- For drinking water networks functioning under high pressures and requiring high-performance anchoring joint.
Main characteristics:
- Pressure class in conformity with Standard EN 545-2010 and ISO 2531-2009
- External coating with 2 barriers, in accordance with EN14628-1:2020 (option PE-G): - Back barrier: a metallic layer of ZnAl(Cu) 85/15 alloy (mini surface density 400 g/m²) applied by spraying molten metal on to the surface of the ductile iron + finishing acrylic layer (Aquacoat) - Front barrier: a continuous thick organic layer of extruded PE + hot melt adhesive layer applied on the back barrier, standard thickness according to DN (table 2 of EN14628-1)
- Internal coating: sulfate resisting blast furnace cement mortar
- EPDM rubber gasket suitable for contact with drinking water (ACS, KTW, WRAS,…)
- Restraining possible with STD Vi joint (without bolts)
® TT PE Download the file