QUICK GS PFA16 DN1000-2000

DN1200-2000

QUICK GS PFA16 DN1000-2000

PRODUCT FAMILY
COUPLINGS - ADAPTORS ,,,
COUPLINGS - ADAPTORS ,,,
RANGE / MARK ®
ASSEMBLY and DISASSEMBLY PRODUCTS
CHOICE OF PRODUCT
Flange adaptors
Main features

Material and coatings

ItemDescriptionMaterialCoating

1

Body

Steel EN 10025 S235JRG2

Blue epoxy powder 250 microns average thickness with a minimum of 200 microns, conforming to EN 14901-1 (PECB)

2

Bolts, Washers

Steel EN 10025 S235JRG2 or S335J2G3 Class 6/8

Zinc

3

Flange Ring

Steel EN 10025 S235JRG2

Blue epoxy powder 250 microns average thickness with a minimum of 200 microns, conforming to EN 14901-1 (PECB)

4

Sealing Ring

Elastomer type EPDM

-

Installation

  • DE margin for assembly pipe: see table Dimensions DE ± (margin for not ovalized pipe). Check than the pipe, to input in the Quick, is not ovalized more than 3mm and that the DE dimension with ovalization is not out of the margin. If not it is necessary to proceed re-rounding pipe see catalogue WATER MAINS for DUCTILE IRON PIPES and FITTINGS
  • Possible adjustment: dimension X ±e (50mm DN 300-2000)
  • Angular deflection in degree + or – 2 degrees
  • Flanges: dimensions in conformity with ISO 7005-2, ISO 2531, EN 1092-2.

Assembly and start up

Description

The flange adaptor type PV allows the connection between a flange and a spigot

An adjustment of the pipe length is possible in the adjustment area (±e).

During the fitment of the pipe (measurement X) in central position the flange adaptor enables an angle of 4°.

Transport

The transport of the pieces must be done professionally in order to avoid damages on the material.

Storing

The flange adaptors must be protected from bad weather and pollution. During a long storage period a protection against UV is necessary.

Assembling in the pipe network

It is necessary to control that the flanges to be connected are clean and not damaged. The pipe to be connected must be perfectly round.

Assembly

  • Implementation of the connection (screws and flat tightening seals to be supplied on site).
  • Unscrew the nuts (2) and remove the counterflange (3) and the tightening seal (4).
  • Write the measurement X on the spigot of the pipe.
  • Slide the counterflange (3) and the tightening seal (4) on the spigot of the pipe.
  • Slide the pipe right into the flange adaptor. If possible it would be necessary to make the assembly in average position.
  • Slide he tightening seal (4) and the counterflange (3) against the body (1).
  • Connect the body (1) and the counterflange (3) with the nuts (2) tightening them in cross.
  • The flange adaptor is then ready for operation.

DNType PV PN10Type PV PN16Type PV PN25Adjustment ±e
mmMeasurement X (mm)Measurement X (mm)Measurement X (mm)mm
8070707540
10070707540
12570707540
15070707540
20070707540
25090909050
300909011050
350909010550
400909010550
450909010550
500909010550
600809010050
700809010050
800909013050
9009017011550
100017018018050
120017018017050
140016022026050
160015021026050
180018024026050
200018024026050
Tightening torque

Nuts

Nm

M16

55 ±4

M20

110 ±10

M24

190 ±10

M27

280 ±15

M30

380 ±20

Solutions