html_17f34136
html_2874fdb3
html_17f34136
html_2874fdb3

Air valve type VENTEX - Standard version

Product family
Pipeline protection

The air valves protect the main:

The device evacuates great air amounts during the filling of the main:

  • allows the inlet of great air amounts (in order to avoid a vacuum effect) during the emptying of the main
  • evacuates small air amounts that are accumulated in the high points of the main during normal working conditions

The air valves are in conformance with EN 1074-4 and have a certificate of sanitary conformity.

Range

Air Valves Type VENTEX exist in a range stretching from DN50 to 200, for pressure PFA10, PFA16 and PFA25.

,

DN Air valve E F H h1 a s
mm mm mm mm mm mm mm
65 390 200 258 165 20 15.3
80-100 467 244 300 215 20 15,3
150 656 405 492 285 24 18,5
200 737 448 580 330 29 20,7

,,

Nozzle diameter
Working pressure (bar) 10 16 25
Diameter (mm) for DN65 2.2 1.7 1.4
Diameter (mm) for DN80 to 200 3 2.4 1.9

,

Connecting flange: 65 type double air valve is fitted with an ISO PN10-16 or ISO PN25 DN60 rotatable flange

Other flanges available:

ISO PN10-16 or ISO PN25 rotatable DN65 flange

DN50 fixed flange.

Technical design

html_2874fdb3
60 Handwheel 10 27 RCA60CSBHV
65 Handwheel 10 27 RCA65CSBHV
80 Handwheel 10 40 RCA80CSBHV
100 Handwheel 10 40 RCB10CSBHV
150 Handwheel 10 115 RCB15CSBHV
200 Handwheel 10 186 RCB20CSBHV
50 Handwheel 16 25 RCA50CSAHV
60 Handwheel 16 27 RCA60CSAHV
65 Handwheel 16 27 RCA65CSAHV
80 Handwheel 16 31 RCA80CSAHV
100 Handwheel 16 40 RCB10CSAHV
150 Handwheel 16 115 RCB15CSAHV
200 Handwheel 16 186 RCB20CSAHV
50 Handwheel 25 25 RCA50CSDHV
65 Handwheel 25 27 RCA65CSDHV
80 Handwheel 25 42 RCA80CSDHV
100 Handwheel 25 44 RCB10CSDHV
150 Handwheel 25 115 RCB15CSDHV
50 Cap 10 25 RCA50CSBH
60 Cap 10 24 RCA60CABH
65 Cap 10 27 RCA65CSBH
80 Cap 10 40 RCA80CABH
100 Cap 10 41 RCB10CABH
150 Cap 10 115 RCB15CABH
200 Cap 10 170 RCB20CABH
50 Cap 16 25 RCA50CSAH
60 Cap 16 27 RCA60CAAH
65 Cap 16 27 RCA65CSAH
80 Cap 16 41 RCA80CAAH
100 Cap 16 40 RCB10CAAH
150 Cap 16 135 RCB15CAAH
200 Cap 16 180 RCB20CAAH
50 Cap 25 25 RCA50CSDH
60 Cap 25 32 RCA60CADH
80 Cap 25 42 RCA80CADH
100 Cap 25 42 RCB10CADH
150 Cap 25 115 RCB15CADH
200 Cap 25 182 RCB20CADH

Features

Fast choice of Ventex

Allows during the emptying of the main with a speed 1m/s

Main DN ≤ 250 DN300-600 DN700-900 DN1000-1200 DN1200-1800
Air Valve DN50, 60, 65 DN80,100 DN150 DN200 2 DN200

This Ventex choice allows, in case of break main, to limit maximal pressure drop 0,3 Bar for a flow rate with a part full gravity pipeline on a given slope: See paragraph Performances.

Material and coating

Item Designation Material
10, 11, 12, 13, 14, 15, 16, 17 Body, Bonnet , Fixing Flanges, Shutter FGS 400/15 or 500-7 coated epoxy 250 µ mini
1-1 Operating stem Stainless steel Z20 C13 type
1-2 Operating nut Cu Zn 39 Pb2 bronze type
1-3 Locked wash Polyamide type 6-6
2-1 ; 2-2 , 2-3 Body-bonnet: bolts and washers Zinc coated class 8-8 steel
3 Body-bonnet gasket EPDM Rubber
4-1 Large orifice seat NBR rubber encapsulated SG 400/15 ductile iron
4-2+4-3+4-4 Seat: bolts and washers Zinc coated class 8-8 steel
5 Nozzle and nozzle control Cu Zn 39 Pb2 bronze rod type
6-1 and 6-2 Float balls EPDM rubber encapsulated Core in steel DC03 or DC04 to EN 10130 and DD11 or DD13 to EN 10111 steel type
7 Shutter gasket EPDM Rubber
8 Ring VAN O FRA EPDM Rubber G 7005
9 V Ring NBR Rubber
18 Operating system bolts and washers Stainless steel class A2
19 Zinc coated class 8-8 steel
20 Operating square (or hand wheel) FGS 400/15 coated polyurethane
21 Baffle Stainless Steel Z6 CN 18-8 type
22 Baffle cover Steel S235JR type coated Epoxy 250 µ
VENTEX_nom

Performances

Water flow in case of break main

Examples of Use: for a main DN600 laid inclined 4mm/m flow water around 1800 m3/h , flow which will not create a depression higher than 0,3b according to graph air flow large orifice below

VENTEX_performances

Air flow large orifice

Air Flow output by large orifice in m3/h (with the pressure of main: air flow = water flow) - Air Flow input by large orifice in m3/h (with the pressure of main: air flow = water flow)

Nozzle air flow

Constant Flow from 1 bar (10MCE)

PFA in Bar 10 16 25
DN in mm 50-65 80-200 50-65 80-200 50-65 80-200
Ø nozzle in mm 2,2 3 1,7 2,4 1,4 1,9
Flow in m3/h 2,7 5 1,6 3,2 1,1 2

Hydraulic

Small and large Float balls: External leakage

No leakage in low pressure from 0,3 bars

VENTEX_debit

Marking

The marking of the valves manufactured by Saint-Gobain refers to the EN 1074-2 and EN 19 international standards.

Markings are either integral markings, cast in the body, or markings made on plates, securely fixed to the body, in accordance with the EN 19 standard specifications.

EN 19 Specifications Saint-Gobain valves process
Table 1 – Valve markings Requirements
1 DN

EN 19 § 4.2.1

Mandatory markings

Shall be integral markings or on a marking plate

Integral
2 PN Integral
3 Material Integral
4 Manufacturer's name or trademark Plate
11 Reference to Standard

EN 19 § 4.3

Supplementary markings

Items 7 to 21 in Table 1 are optional

Plate
12 Melt identification Integral
16 Quality test Printed on body
18 Manufacturing date Plate
21 Closing direction Plate + sticker on body
VENTEX_marquage
VENTEX_marquage
VENTEX_marquage

Installation

VENTEX_installation
1.
VENTEX_installation
2.
  1. Mounting on tee: central operating system allows, without water cut of sector, the regular maintenance of Ventex in particular change of the floats ball
  2. Mounting with reducing flange
  3. Mounting with gate valve: only for a repairing without water cut: operating system or shutter gasket insert gate valve
  4. Mounting with two air valves DN200: for pipes DN1400 up to DN1800: to realize according to sketch on a tee 3 equal socket and a special Blank flange
Ventex_SR_installation
VENTEX_installation
4.

Documents