NAT-ALP anchored Collar

Assembly instructions for NATURAL-ALPINAL collar

Product family
Fittings

Features

Placing the component parts

First place the gland “a” → anchored gasket “b” → spacer “c” → leaktightness gasket “d” on the pipe.

Be attentive to the order of the component parts when placing them.

Item Description
d Leaktightness gasket
c Spacer
b Anchored gasket
a Gland
Notice_Manchon_NAT-ALP

Draw the depth for assembly

Draw the dimension “distance P” on the spigot of the pipes to be assembled.

(P = minimal distance between the side to be assembled and the spigot end)

DN P ± 10 L J Max
80 60 280 160
100 60 300 180
125 60 310 190
150 60 300 180
200 60 331 211
250 60 330 210
300 60 340 220
350 70 350 210
400 70 440 300
500 70 470 330
Notice_Manchon_NAT-ALP

Placing the collar

Lubricate the gasket chamber with the PAM lubricant. Slide the collar on the pipe, place the gasket in the chamber. Verify that the assembly depth is good, marking “P” must be visible.

Notice_Manchon_NAT-ALP

Placing the spacer

Lubricate the threads of the bolts with a mechanical paste (eg CASTROL or MOBIL), place them (one out of two in the spacer) and tight them following the torque according to DN, see the torque chart.

Angular deflection : first tight aligned at 8 m.daN torque, then apply the deviation (max 2°), then tight again at recommended torque according to DN.

Torque (m.daN)
DN 80 100 125 150 200 250 300 350 400 450
Torque  12 12 18 20 20 20 20 20 30 30
Notice_Manchon_NAT-ALP
Verify that there is a regular gap between the spacer and the collar side to be assembled

Placing the gland

Bring the anchored gasket closer in order to touch the spacer, then bring the gland closer.

Place the spindles and tight them at 8 m.daN torque.

Notice_Manchon_NAT-ALP
Verify that there is a regular gap between the spacer and the gland