Automatic degassing Air Valve Type 100

Product family
Pipeline protection

Air valves available in 4 models: model 100, model 110, model 111, model 112 and model 113

The Automatic Degassing Air Valve is used on pressurized pipes to evacuate the air or a mix of air/water accumulated in the high points of the pipeline during normal duty. It has to be fitted on each track peak, meant as slope changing.

Technical design

html_m6314bf70
Type 100
100 16 ¾ 138 161 4.5 204001
100 25 ¾ 138 161 4.5 204003
100 16 1 138 161 5 204005
100 25 1 138 161 4.5 204007
110 16 ¾ 138 184 4.5 RCF07AEAH
110 16 1 138 184 4.5 RCF10AEAH
110 25 1 138 184 4.5 RCF10AEDH
111 16 ¾ 138 230.5 4.5 RCF07BAAH
111 25 ¾ 138 230.5 4.5 RCF07BNDH
111 16 1 138 230.5 4.5 RCF10BNAH
111 25 1 138 230.5 4.5 RCF10BNDH
112 16 1 215 138 7.5 RCA40AFAH
112 25 1 215 138 10.1 RCA40AFDH
112 16 1 218 138 10 204010
113 16 1 262.5 138 8 RCA40BTXH
113 25 1 262.5 138 10.1 RCA40BTCH
113 16 1 265.5 138 10.5 181190
113 25 1 265.5 138 11 204009
113 25 1 265.5 138 12 181597

Features

Material and coating

Item Designation Material Coatings
1 Body Ductile iron FGS 400/15 or 500-7 Blue Epoxy 250 microns
2 Cover Ductile iron FGS 400/15 or 500-7 Blue Epoxy 250 microns
3 Screw Stainless steel A2  
4 Washer Stainless steel A2  
5 Float ABS  
6 Nozzle Polyamide  
7 Nut Polyamide  
8 Gasket EPDM  
9 O ring EPDM  
10 Gasket EPDM  
11 Adjusting screw Stainless steel A2  
12 Pin Stainless steel A2  
13 Air valve Brass  
Purgeur_Type_100_nomenclature

Performances

Purgeur_Type_100_nomenclature

Applicable Standards

Hydraulic test

Every single air valve is subjected to hydraulic test in accordance with the prescription EN 1074:

  • Test of float at minimum declared pressure according to EN 1074-1 standard (0,5 bar).

Product test

  • Control of coatings: test of thickness, holiday test, impact test, MIBK test.

Conformity to the standards

Product:

  • EN 1074-1
  • EN 1074-4

Flanges connection:

  • EN 1092-2
  • ISO 7005-2

Suitability for potable water:

  • D.M. 174 for applicable parts (ex : C.M. 102 du 02/12/78)
  • Conformity with foreign norms: KTW (Germany), WRC (UK), ACS (France)

Marking

On the body:

  • Type of ductile iron
  • Model code
  • Manufacturer's logo
  • Fusion date

On the labels:

  • Nominal diameter in mm (DN)
  • Nominal pressure in mm (PN)
  • Maximum operating pressure (PFA)
  • Production number
  • Manufacturer's logo

Valves selection

The operating pressure value (PFA) is defined depending on the pressure of the pipeline. Moreover this is important to verify that the operating temperature is between 0° C and 40°C.

The maximum flow allowable depends on air valve PFA and is calculated using the formula:

Q = v*A; where “v” is the outlet air speed from a small orifice (measured: 195 m/s) with pressure more than 1,3 bar.

PFA Orifice Diameter (mm) Max Flow (m3/h)
25 1,75 1,69
16 2,25 2,79

To evaluate if a single vent is enough, it must be check the air flow which is to be evacuated, which depends on the devices fitted on the pipe (i.e. pump thrust, etc…) and the solubility of air in water (Bunsen coefficient, function of temperature and pressure).

Instructions for use

Storage

The air valve will have to be stored (if possible) in covered places, as possible protected from the sun and from the rain and generally from the atmospheric agents. Moreover it will have to be avoided that the seal of the air valves are in contact with dust or gravel.

Installation

The automatic degassing air valve is installed where the pipe have a slope variation, for eliminating the air balls which can be accumulated in the higher points or moving inside the duct.

Maintenance

In order to grant the possibility of future inspections, it is necessary during the installation to fit a manual sectioning device (i.e. gate valve or butterfly valve) between the pipe flange and the air valve. In this way it will be possible to maintain without interrupting service. It is important to make sure that air valve can be dissembled while the pipe is still in service.