NATURAL PUR BioZinalium pipes DN100 to 600 with UNIVERSAL STANDARD socket
Technical design
| 100 | 5.970 | C100 | 6.1 | 118 | 121.4 | 140 | 188 | 17.04 | NGB10B60WQ |
| 150 | 5.970 | C64 | 6.2 | 170 | 173.4 | 148 | 230 | 29.01 | NGB15C60WQ |
| 200 | 5.970 | C64 | 6.5 | 222 | 225.2 | 155 | 290 | 35.01 | NGB20C60WQ |
| 250 | 5.970 | C50 | 6.8 | 274 | 276.8 | 166 | 350 | 46.16 | NGB25D60WQ |
| 300 | 5.970 | C50 | 7.4 | 326 | 328.8 | 180 | 408 | 60.05 | NGB30D60WQ |
| 400 | 5.970 | C40 | 8.1 | 429 | 431.9 | 176 | 510 | 85.44 | NGB40F60WQ |
| 500 | 5.970 | C40 | 9.3 | 532 | 535.0 | 200 | 625 | 123.36 | NGB50F60WQ |
| 600 | 5.970 | C40 | 10.9 | 635 | 638.2 | 209 | 740 | 169.36 | NGB60F60WQ |
Features
Legend:
-
DN: nominal diameter
-
Lu: laying length, in m
-
Class: pressure class according to EN 545 and ISO 2531
-
e: nominal thickness according to ISO 2531, in mm
-
ØDE: external nominal diameter of the barrel according to EN 545 and ISO 2531, in mm
-
ØDI: internal nominal diameter of the socket, in mm
-
P: nominal depth of the socket, in mm
-
ØB: nominal diameter of the socket, in mm
-
Mass: total mass per metre (including polyurethane coating and socket), determined with the nominal thickness, in kg/m
-
Reference: commercial reference Saint-Gobain PAM
Field of use:
-
Aggressive or soft waters
Main characteristics:
- Pressure class in conformity with Standard EN 545-2010 and ISO 2531-2009
- External BioZinalium® coating consists of two layers:
- a layer of zinc-aluminium 85/15 alloy, enriched with copper, with a minimum surface density of 400g/m²), applied by spraying molten metal onto the surface of the iron, using an electric arc spray gun, from ZnAl (Cu) alloy wire
- a protective layer of Aquacoat (semi-permeable), a water-based blue acrylic of average thickness 80 microns applied using a spray gun (RAL 5005)
- Internal coating: 800 microns mini thick layer of sand-coloured polyurethane
- Standard joint in alimentary elastomer EPDM (ACS, KTW, WRAS,…)
- Vi anchoring without bolts
Type of soils:
BioZinalium® coating can be in contact with all type of soil, as defined in Annex D.2.2 of EN545:2010, except:
-
peaty and acid soils
-
soils containing wastes, scraps, ashes, slags or soils contaminated by industrial effluents or other wastes
-
soils located under the level of the marine water table with a resistivity lower than 500 Ω cm
In such soils, and also in the event of stray currents, it is recommended to use other types of external coatings for more aggressive soils (TT PE or TT PUX ranges).