NATURAL PUR BioZinalium pipes DN1500 to 2000 with PAMLOCK socket + Weld bead PLK

Product family
Pipes

Technical design

Tuyau_Std_PAMLOCK_PUR
1500 8.110 C25 18.0 1565 1571.1 315 1757.3 180 693.19 NPC15H80WQ
1600 8.110 C25 18.9 1668 1674.2 325 1868.0 195 781.72 NPC16H80WQ
1800 8.080 C25 20.7 1875 1881.5 350 2075.3 222 962.11 NPC18H80WQ
2000 8.025 C25 22.5 2082 2088.8 394 2287.0 243 1193.30 NPC20H80WQ

Features

Legend:

  • DN: nominal diameter

  • Lu: laying length, in m

  • Class: pressure class according to EN 545 and ISO 2531

  • e: nominal thickness according to ISO 2531, in mm

  • ØDE: external nominal diameter of the barrel according to EN 545 and ISO 2531, in mm

  • ØDI: internal nominal diameter of the socket, in mm

  • P: nominal depth of the socket, in mm

  • ØB: nominal diameter of the socket, in mm

  • c: weld bead position, in mm

  • Mass: total mass per metre (including polyurethane coating and socket), determined with the nominal thickness, in kg/m

  • Reference: commercial reference Saint-Gobain PAM

Field of use:

  • Aggressive or soft waters

Main characteristics:

  • Pressure class in conformity with Standard EN 545-2010 and ISO 2531-2009
  • External Zinalium coating consists of two layers:
    • a layer of zinc-aluminium 85/15 alloy, enriched with copper, with a minimum surface density of 400g/m²), applied by spraying molten metal onto the surface of the iron, using an electric arc spray gun, from ZnAl (Cu) alloy wire
    • a protective layer of Aquacoat (semi-permeable), a water-based blue acrylic of average thickness 80 microns applied using a spray gun (RAL 5005)
  • Internal coating: 800 microns mini thick layer of sand-coloured polyurethane
  • Standard joint in alimentary elastomer EPDM (ACS, KTW, WRAS,…)

Type of soils:

BioZinalium® coating can be in contact with all type of soil, as defined in Annex D.2.2 of EN545:2010, except:

  • peaty and acid soils

  • soils containing wastes, scraps, ashes, slags or soils contaminated by industrial effluents or other wastes

  • soils located under the level of the marine water table with a resistivity lower than 500 Ω cm

In such soils, and also in the event of stray currents, it is recommended to use other types of external coatings for more aggressive soils (TT PE or TT PUX ranges).