Programmable Battery Powered - E3113-46 / E4113-46
The normally closed automatic valve opens in response to pulses from a battery-powered control unit, regardless of changes in upstream pressure. The digital controller allows up to three different daily programs.
It is mainly used for discharge in the bottom of the line or to regulate the flow inside hydraulic circuits. Equipped with a visual position indicator and made entirely of stainless steel and ductile iron, the valve reduces pressure losses, vibrations and damage related to the phenomenon of cavitation.
Flange drilling according to EN 1092/2, different on request.
Certification and testing according to EN 1074.
Technical design
| E3113-46 | 80 | 10 16 | 31 | E33A8016P46 |
| E3113-46 | 100 | 10 16 | 37 | E33B1016P46 |
| E3113-46 | 125 | 10 16 | 57 | E33B1216P46 |
| E3113-46 | 150 | 10 16 | 64 | E33B1516P46 |
| E3113-46 | 200 | 16 | 110 | E33B2016P46 |
| E3113-46 | 200 | 10 | 110 | E33B2010P46 |
| E3113-46 | 250 | 16 | 188 | E33B2516P46 |
| E3113-46 | 250 | 10 | 188 | E33B2510P46 |
| E3113-46 | 300 | 16 | 305 | E33B3016P46 |
| E3113-46 | 300 | 10 | 305 | E33B3010P46 |
| E3113-46 | 400 | 10 | 516 | E33B4010P46 |
| E3113-46 | 500 | 16 | 862 | E33B5016P46 |
| E3113-46 | 500 | 10 | 862 | E33B5010P46 |
| E3113-46 | 600 | 16 | 1002 | E33B6016P46 |
| E3113-46 | 600 | 10 | 1002 | E33B6010P46 |
| E3113-46 | 400 | 16 | 516 | E33B4016P46 |
| E4113-46 | 3/4" | 10 16 | 1.7 | E43A1916P46 |
| E4113-46 | 40/50 | 10 16 | 25 | E43A5016P46 |
| E4113-46 | 65 | 10 16 | 27 | E43A6516P46 |
| E4113-46 | 80 | 10 16 | 31 | E43A8016P46 |
| E4113-46 | 100 | 10 16 | 49 | E43B1016P46 |
| E4113-46 | 150 | 10 16 | 97 | E43B1516P46 |
| E4113-46 | 200 | 10 | 154 | E43B2010P46 |
| E4113-46 | 200 | 16 | 154 | E43B2016P46 |
| E4113-46 | 250 | 10 | 265 | E43B2510P46 |
| E4113-46 | 250 | 16 | 265 | E43B2516P46 |
| E4113-46 | 300 | 10 | 441 | E43B3010P46 |
| E4113-46 | 300 | 16 | 441 | E43B3016P46 |
| E4113-46 | 400 | 10 | 784 | E43B4010P46 |
| E4113-46 | 400 | 16 | 784 | E43B4016P46 |
| E4113-46 | 600 | 10 | 2250 | E43B6010P46 |
| E4113-46 | 600 | 16 | 2250 | E43B6016P46 |
Features
Applications
- Off-shoot of the main pipeline to regulate the flow with specific programs, in the absence of electrical power.
- For the discharge of bottom- line waste in water supply networks and hydraulic circuits.
Accessories
- Manometers.
- Self-cleaning high capacity filter.
- Container to estate of water IP 68 For the submerged installations.
- Limiter of opening manual
Directions for use
- The inlet and outlet pressure, flow rate and application values are required for sizing and cavitation analysis.
- Oversizing the valve can cause an excessive pressure-drop during opening, preventing it from closing.
Optional configurations
- Valve with on-off regulation via independent programmer and anti-backflow system.
- Valve with on-off regulation by means of a programmer and rapid relief pilot.
Operating conditions
- Fluid: treated water.
- Minimum pressure: 0,7 bar.
- Maximum pressure: 16 bar. Higher on request.
- Maximum temperature: 70 °C.
Using the programmer
- The programming procedure is illustrated in the installation manual supplied with the valve.
How it works
The hydrovalve is controlled by a battery operated digital unit that pulses the solenoid (5) to open the valve and allows up to three different daily programs. The flow accelerator (4) is present in models with a diameter of 150 mm or larger.
When the solenoid (5) is energized, the pressure is discharged from the chamber (10) so as to cause the shutter (11) to rise and open the valve. In response to a different impulse, the solenoid (5) instead directs the pressure into the chamber (10) so as to interrupt, with the descent of the shutter (11), the flow through the seat (12).
The pressure towards the main chamber (10) is controlled by a needle valve (2), necessary to avoid possible water hammer during the closing phase. A filter (3), installed upstream, also protects the solenoid and the other components of the circuit from contact with impurities and debris.
Installation diagram
The following image shows the recommended installation scheme of the valve positioned on a bottom line, branching from the main line.
Shut-off devices (1, 2) and bypasses are provided, important for maintenance, and a filter (3), which retains any impurities.
The installation of combined anti-water hammer vents (4) upstream of the valve is also recommended.