RepLINK - Stainless steel repair clamp
RepLINK - Stainless steel repair clamp
RepLINK - Stainless steel repair clamp
RepLINK - Stainless steel repair clamp
REPLINK

RepLINK - Stainless steel repair clamp Type T, U and Z

Product family
Couplings and assembling

Technical design

RepLINK - Stainless steel repair clamp
Repair clamp (triple band)
300 330 7 T 3 x L=200 mm 12.2 MRY30CAXHEN
330 360 6 T 3 x L=200 mm 12.2 MRY33CAXHEN
360 390 5.5 T 3 x L=200 mm 12.8 MRY36CAXHEN
390 420 4 T 3 x L=200 mm 12.8 MRY39CAXHEN
420 450 3.5 T 3 x L=200 mm 13.6 MRY42CAXHEN
450 480 3 T 3 x L=200 mm 13.7 MRY45CAXHEN
480 510 2.5 T 3 x L=200 mm 13.8 MRY48CAXHEN
510 540 2 T 3 x L=200 mm 13.8 MRY51CAXHEN
540 570 2 T 3 x L=200 mm 13.9 MRY54CAXHEN
570 600 2 T 3 x L=200 mm 14.3 MRY57CAXHEN
600 630 2 T 3 x L=200 mm 14.4 MRY60CAXHEN
630 660 2 T 3 x L=200 mm 14.4 MRY63CAXHEN
660 690 2 T 3 x L=200 mm 14.7 MRY66CAXHEN
690 720 2 T 3 x L=200 mm 15.4 MRY69CAXHEN
720 750 2 T 3 x L=200 mm 15.5 MRY72CAXHEN
300 330 7 U 4 x L=300 mm 18.2 MRY30CAXHGN
330 360 6 U 4 x L=300 mm 18.4 MRY33CAXHGN
360 390 5.5 U 4 x L=300 mm 18.7 MRY36CAXHGN
390 420 4 U 4 x L=300 mm 19.2 MRY39CAXHGN
420 450 3.5 U 4 x L=300 mm 19.5 MRY42CAXHGN
450 480 3 U 4 x L=300 mm 19.7 MRY45CAXHGN
480 510 2.5 U 4 x L=300 mm 19.9 MRY48CAXHGN
510 540 2 U 4 x L=300 mm 20 MRY51CAXHGN
540 570 2 U 4 x L=300 mm 20.8 MRY54CAXHGN
570 600 2 U 4 x L=300 mm 21.4 MRY57CAXHGN
600 630 2 U 4 x L=300 mm 21.6 MRY60CAXHGN
630 660 2 U 4 x L=300 mm 21.7 MRY63CAXHGN
660 690 2 U 4 x L=300 mm 22.4 MRY66CAXHGN
690 720 2 U 4 x L=300 mm 22.6 MRY69CAXHGN
720 750 2 U 4 x L=300 mm 23.2 MRY72CAXHGN
300 330 7 Z 7 x L=500 mm 31.3 MRY30CAXHHN
330 360 6 Z 7 x L=500 mm 31.8 MRY33CAXHHN
360 390 5.5 Z 7 x L=500 mm 32.2 MRY36CAXHHN
390 420 4 Z 7 x L=500 mm 33 MRY39CAXHHN
420 450 3.5 Z 7 x L=500 mm 34.1 MRY42CAXHHN
450 480 3 Z 7 x L=500 mm 34.2 MRY45CAXHHN
480 510 2.5 Z 7 x L=500 mm 34.3 MRY48CAXHHN
510 540 2 Z 7 x L=500 mm 35.8 MRY51CAXHHN
540 570 2 Z 7 x L=500 mm 36.7 MRY54CAXHHN
570 600 2 Z 7 x L=500 mm 36.9 MRY57CAXHHN
600 630 2 Z 7 x L=500 mm 38.2 MRY60CAXHHN
630 660 2 Z 7 x L=500 mm 38.4 MRY63CAXHHN
660 690 2 Z 7 x L=500 mm 40.3 MRY66CAXHHN
690 720 2 Z 7 x L=500 mm 40.5 MRY69CAXHHN
720 750 2 Z 7 x L=500 mm 40.5 MRY72CAXHHN

Features

Field of use

The multi bolts repair clamps are part of the pipelines repair range of PAM NEXUS.

The repair clamps are used for the repair of localized breakages or circumferential breakages on pipelines of every kind of material for drinkable water service.

The longitudinal breakages haven’t to be exceeded the 35% of the totally width of the clamp while the circumferential breakages haven’t to be, as maximum distance from the braked extremity, upper than 10mm.

Material and coating

  • Belt in stainless steel AISI 304 with a minimum thickness of 0,8 mm and minimum width of 200mm;
  • Claps in ductile cast iron GS 500-7UNI EN 1563 coated with blue epoxy powder 250 microns average thickness with a minimum of 200 microns, conforming to EN 14901 (PECB);
  • Lock of the plate of the clamp in ductile iron, through a strong stainless steel bar, housed in an appropriate seat;
  • Gasket in EPDM APE55N rubber with insert in vulcanized stainless steel AISI 304, thickness of 1,5mm in the area of the closing of the clamp;
  • Screws with hexagonal butt with partial thread and hexagonal nut according to UNI 5587, in steel class 6.S, protected with a galvanizing Zn/Fe coating and tropical hexavalent chromium passivation;
  • Materials suitable for drinking water.

Available upon request:

  • Gasket in EPDM suitable for drinking water;
  • Bolts in stainless steel.

The ductile iron clamps and their geometrical conformity allow a higher resistance of tightening, thus ensuring a regular distribution of the tensions along the entire width of the collar and therefore guaranteeing an excellent seal reliability over the time.

Part Material Coating
Body Stainless Steel type Z7 CN 18.09  
Gasket EPDM  
Clamp Ductile Iron GS Blue epoxy powder 250 microns average thickness with a minimum of 200 microns, conforming to EN 14901-1 (PECB)
Bolts Steel class 6.S Zinc
REPLINK_manchon_reparation_inox
REPLINK_manchon_reparation_inox

Exercise conditions

Concerning the exercise conditions of the clamps, here follow the diagram with the working pressure and the external diameter of the pipeline.

Curve 1: value of the test pressure carried out on the pipeline with longitudinal breakage equal to the 35% of the repair clamp belt’s width;

Curve 2: value of the test pressure carried out on the pipeline with circumferential breakage

Note: the pressure values indicated in the diagram are guaranteed for all the clamps installed on the pipeline with roughness similar to the ductile cast iron pipes usually on sale.

REPLINK_manchon_reparation_inox

Applicable Standard

Tests

All products of NEXUS range are manufactured and tested in a factory in compliance with ISO EN9001 and ISO 14000.

Coating tests: thickness test, holiday test, impact test, MIBK test.

Conformity to Standards

Suitability with potable water in accordance with:

  • D.M. 174/ (ex C.M.S. 102 del 2/12/78);
  • Foreign regulations: KTW, ACS, WRAS.

Installation instructions

Storage

Repair clamps have to be stored in covered places, protected from the sun, rain and all other atmospheric agents. Moreover it has to be avoided that the seal of the same valves comes in contact with dust and dirt.

Installation

The bolt in the middle, with more length respect to the others, allows an easy mounting of the clamp on the pipeline to be repaired.

Operations to be made during installation:

  1. Clean the part of the pipe to be repaired;
  2. Put the repair clamp on the cut or the hole;
  3. Ensure that the tapered limb of the gasket is not folded on itself in any point, and that it is well extended on the pipe to be repaired; (Note: we recommend greasing the tapered limb with soapy water, grease or Vaseline.)
  4. Put the opposite terminal of the clamp on the tapered limb;
  5. Insert the bolts in their respective position to tighten them manually;
  6. Rotate the repair clamp in the direction indicated by the arrow printed on the label (necessary operation for the definitive correct extension of the tapered limb) making sure that the damaged section of the pipe remains under the section of vulcanized plate in the gasket;
  7. Tighten the screws uniformly and gradually so that the two stainless steel clamps come together during the tightening, always parallel to each other according to the recommended tightening torque.

Note: during this operation make sure that the vulcanized part of the gasket does not strain in order not to compromise the seal.