Tuyau_SC_CLASSIC_PUX_Standard

TT PUX pipes DN150 to 2000 with STANDARD socket

Application
Product family
Pipes

Technical design

Tuyau_SC_CLASSIC_PUX_Standard
150 6.000 C40 4.5 170.0 173.4 100.5 220.8 22.720 SSB15Q60AH
200 6.000 C40 4.7 222.0 225.2 106.5 275.1 30.990 SSB20Q60AH
250 6.000 C40 5.5 274.0 276.8 105.5 328.6 43.218 SSB25Q60AH
250 6.000 C50 6.4 274 276.8 105.5 328.6 49.260 SSB25D60AH
300 6 C40 6.2 326 328.8 107.5 385.3 56.625 SSB30F60AH
350 6.000 C30 6.4 378.0 380.9 110.5 444.5 68.800 SSB35G60AH
400 6.000 C30 6.5 429.0 431.9 112.5 494.6 79.400 SSB40G60AH
450 6.000 C30 6.9 480.0 483.0 115.5 546.5 93.800 SSB45G60AH
500 6.000 C30 7.5 532.0 535.0 117.5 600.9 111.100 SSB50G60AH
500 6.000 C40 9.3 532.0 535 117.5 600.9 133.000 SSB50F60AH
600 6.000 C30 8.7 635.0 638.1 132.5 712.0 150.600 SSB60G60AH
700 6.960 C25 8.8 738 741.7 192.0 821.9 189.676 SSB70H70AH
800 6.950 C25 9.6 842 845.8 197.0 935.6 232.964 SSB80H70AH
900 6.950 C25 10.6 945 948.9 200.0 1043.4 283.583 SSB90H70AH
1000 6.960 C25 11.6 1048 1052.0 203.0 1152.4 338.907 SSC10H70AH
1100 8.190 C25 12.6 1152 1155.1 225.0 1263.7 400.757 SSC11H80AH
1200 8.190 C25 13.6 1255 1260.0 235.0 1373.7 467.184 SSC12H80AH
1400 8.170 C25 15.7 1462 1467.9 245.0 1592.1 641.175 SSC14H80AH
1500 8.160 C25 16.7 1565 1571.1 265.0 1709.8 727.635 SSC15H80AH
1600 8.160 C25 17.7 1668 1674.2 265.0 1815.9 815.319 SSC16H80AH
1800 8.150 C25 19.7 1875 1881.5 275.0 2032.2 1003.828 SSC18H80AH
2000 8.130 C25 21.8 2082 2088.8 290.0 2259.0 1219.779 SSC20H80AH

Features

Legend:

  • DN: nominal diameter

  • Lu: laying length, in m

  • Class: pressure class according to EN 545 and ISO 2531

  • e: nominal thickness according to ISO 2531, in mm

  • ØDE: external nominal diameter of the barrel according to EN 545 and ISO 2531, in mm

  • ØDI: internal nominal diameter of the socket, in mm

  • P: nominal depth of the socket, in mm

  • ØB: nominal diameter of the socket, in mm

  • Mass: total mass per metre (including cement coating and socket), determined with the nominal thickness, in kg/m

  • Reference: commercial reference Saint-Gobain PAM

Field of use:

  • For drinking water networks and other water networks (except sewage water)

  • For high corrosive soils, industrial pollution zones

Main characteristics:

  • Pressure class in conformity with Standard EN 545-2010 and ISO 2531-2009
  • External coating: polyurethane coating (900 microns) on the barrel, red-brown epoxy (300 microns) on spigot end and inside socket - conformity to EN 14901 and EN 15189
  • Internal coating: sulfate resisting blast furnace cement mortar
  • Standard joint in alimentary elastomer EPDM (ACS, KTW, WRAS,…)

Available anchoring joints in the range DN700 to 2000:

Pipes Class C can be anchored. Please refer to below information:

DN

Anchoring joints

DN700 to 1200 STANDARD Ve anchoring system
DN700 to 1600 UNIVERSAL Ve anchoring system

DN1400 to 2000

PAMLOCK anchoring system.

Documents