INTEGRAL BioZinalium pipes DN150 to 1600 with UNIVERSAL STANDARD socket + Weld bead Ve
Technical design
| 150 | 5.970 | 6.2 | 4.0 | 170 | 173.4 | 148.0 | 230.0 | 95 | 29.100 | 60 | TFB15N60BP |
| 200 | 5.970 | 6.5 | 4.0 | 222 | 225.2 | 155.0 | 290.0 | 100 | 40.100 | 52 | TFB20N60BP |
| 250 | 5.970 | 6.8 | 4.0 | 274 | 276.8 | 166.0 | 350.0 | 110 | 52.300 | 46 | TFB25N60BP |
| 300 | 5.970 | 7.4 | 4.0 | 326 | 328.8 | 180.0 | 408.0 | 115 | 67.400 | 41 | TFB30N60BP |
| 350 | 5.970 | 7.7 | 5.0 | 378 | 380.9 | 184.0 | 463.0 | 115 | 83.600 | 38 | TFB35N60BP |
| 400 | 5.970 | 8.1 | 5.0 | 429 | 431.9 | 176.0 | 510.0 | 113 | 98.300 | 35 | TFB40N60BP |
| 450 | 5.970 | 8.6 | 5.0 | 480 | 483.0 | 190.0 | 570.0 | 120 | 117.400 | 32 | TFB45N60BP |
| 500 | 5.970 | 9.3 | 5.0 | 532 | 535.0 | 200.0 | 625.0 | 125 | 139.300 | 30 | TFB50N60BP |
| 600 | 5.970 | 10.9 | 5.0 | 635 | 638.2 | 209.0 | 740.0 | 135 | 187.900 | 30 | TFB60N60BP |
| 700 | 6.900 | 10.8 | 6.0 | 738 | 741.7 | 250.0 | 855.0 | 158 | 226.500 | 27 | TFB70N70BP |
| 800 | 6.900 | 11.7 | 6.0 | 842 | 845.8 | 261.0 | 980.0 | 150 | 278.200 | 25 | TFB80N70BP |
| 900 | 6.900 | 12.6 | 6.0 | 945 | 948.9 | 280.0 | 1087.0 | 155 | 339.940 | 25 | TFB90N70BP |
| 1000 | 6.900 | 13.5 | 6.0 | 1048 | 1052.0 | 279.5 | 1191.0 | 165 | 393.710 | 25 | TFC10N70BP |
| 1200 | 8.150 | 15.3 | 6.0 | 1255 | 1260.0 | 279.5 | 1415.0 | 170 | 524.450 | 20 | TFC12N80BP |
| 1400 | 8.090 | 17.1 | 9.0 | 1462 | 1468.5 | 330.0 | 1640.1 | 190 | 714.670 | 16 | TFC14N80BP |
| 1600 | 8.090 | 18.9 | 9.0 | 1668 | 1674.2 | 330.0 | 1874.0 | 195 | 901.800 | 16 | TFC16N80BP |
Features
Legend:
-
DN: nominal diameter
-
Lu: laying length, in m
-
e: thickness according to EN598 + A1 – August 2009, in mm
-
er: thickness of the cement mortar, in mm
-
ØDE: external nominal diameter of the barrel according to EN598 + A1 – August 2009, en mm
-
ØDI: internal nominal diameter of the socket, in mm
-
P: nominal depth of the socket, in mm
-
ØB: nominal diameter of the socket, in mm
-
c: weld bead position, in mm
-
Mass: total mass per meter (including cement coating and socket), determined with the nominal thickness, in kg/m
-
Reference: commercial reference Saint-Gobain PAM
Field of use:
-
Separate sewer system and combined sewer system
-
Application: gravity flow and rising main sewerage systems
-
Type of effluent: domestic wastewater and rainwater
-
Perfectly watertight
-
For effluents between pH4 and pH12
-
For the soils with 6 < pH < 9
-
Majority of the soils, except the acid peaty and polluted soils
-
Suitable for clay soils
-
Resistivity of the soils: please refer to above drawing
Main characteristics:
-
External coating BioZinalium: a layer of zinc-aluminium alloy enriched with copper Zn85Al15 (Cu), with surface density of 400 g/m² covered with a protective red (RAL 3011) layer AQUACOAT 80 μm (mini average), without VOC and without BPA.
-
Internal lining: aluminous cement mortar CALCOAT
-
Socket coating: zinc rich paint 40 μm or zinc-aluminium 200 g/m² + red AQUACOAT 160 μm (mini average)
-
Spigot coating: zinc-aluminium (Cu) 400 g/m² + red AQUACOAT 160 μm (mini average)
-
Standard Gasket in Nitrile
-
EN 598 / CE Marking
-
NF mark
-
Declaration of performances DoP-INTEGRAL005EN
- Designed in accordance with applicable regulations:
- NF EN 476: general stipulations regarding components used in systems
- NF EN 752: design of sewerage projects
- NF EN 1610: acceptance of structures
- CCTG: Fascicule 70 (sewage work)