MINERAL M200 BioZinalium pipes DN150 to 1600 with STANDARD socket
Technical design
| 150 | 6.000 | 5.0 | 4.0 | 170 | 173.4 | 100.5 | 220.8 | 40 | 23.825 | USB15S60BP |
| 200 | 6.000 | 5.1 | 4.0 | 222 | 225.2 | 106.5 | 275.1 | 40 | 32.009 | USB20S60BP |
| 250 | 6.000 | 5.3 | 4.0 | 274 | 276.8 | 105.5 | 328.6 | 38 | 41.032 | USB25S60BP |
| 300 | 6.000 | 5.6 | 4.0 | 326 | 328.8 | 107.5 | 385.3 | 35 | 51.258 | USB30S60BP |
| 350 | 6.000 | 6.0 | 5.0 | 378 | 380.9 | 110.5 | 464.2 | 32 | 65.600 | USB35S60BP |
| 400 | 6.000 | 6.3 | 5.0 | 429 | 431.9 | 112.5 | 516.2 | 30 | 77.500 | USB40S60BP |
| 450 | 6.000 | 6.7 | 5.0 | 480 | 483.0 | 115.5 | 574.2 | 29 | 91.700 | USB45S60BP |
| 500 | 6.000 | 7.0 | 5.0 | 532 | 535.0 | 117.5 | 629.2 | 28 | 105.400 | USB50S60BP |
| 600 | 6.000 | 7.7 | 5.0 | 635 | 638.1 | 132.5 | 738.5 | 26 | 136.900 | USB60S60BP |
| 700 | 6.96 | 9.6 | 6 | 738.0 | 741.7 | 192 | 863 | 29 | 199 | USB70E70BP |
| 800 | 6.95 | 10.4 | 6 | 842 | 845.8 | 197 | 974 | 28 | 243.600 | USB80E70BP |
| 900 | 6.95 | 11.2 | 6 | 945 | 948.9 | 200 | 1082 | 27 | 291.5 | USB90E70BP |
| 1000 | 6.96 | 12.0 | 6 | 1048 | 1052 | 203 | 1191 | 26 | 343.1 | USC10E70BP |
| 1200 | 8.19 | 15.3 | 6 | 1255 | 1260 | 235 | 1412.5 | 29 | 507.600 | USC12N80BP |
| 1400 | 8.170 | 17.1 | 9 | 1462 | 1467.9 | 245 | 1592.1 | 28 | 678.900 | USC14N80BP |
| 1500 | 8.160 | 18.0 | 9 | 1565 | 1571.1 | 265 | 1709.8 | 27 | 764.700 | USC15N80BP |
| 1600 | 8.16 | 18.9 | 9 | 1668 | 1674.2 | 265 | 1815.9 | 27 | 851.300 | USC16N80BP |
Features
Legend:
-
DN: nominal diameter
-
Lu: laying length, in m
-
e: nominal thickness according to EN598 + A1-08/2009, in mm
-
er: thickness of cement mortar
-
ØDE: external nominal diameter of the barrel according to EN598 + A1-08/2009, in mm
-
ØDI: internal nominal diameter of the socket, in mm
-
P: nominal depth of the socket, in mm
-
ØB: nominal diameter of the socket, in mm
-
Mass: total mass per metre (including cement coating and socket), determined with the nominal thickness, in kg/m
-
PFA: according to EN598 + A1-08/2009, in bar
-
Reference: commercial reference Saint-Gobain PAM
Main characteristics:
-
Internal lining: cement mortar M200 (please contact us for thickness higher than “er”)
-
Joint gasket material: Nitrile rubber
-
External coating BioZinalium: a layer of zinc-aluminium alloy enriched with copper Zn85Al15 (Cu), with surface density of 400 g/m² covered with a protective red (RAL 3011) layer AQUACOAT 80 μm (mini average), without VOC and without BPA.
Field of use:
Lining M200 vs fluids:
-
Sea waters, recycled waters, waste waters and brines
-
Slurries of waste materials to disposal
-
Effluents/slurries of pH4 to 12
Note: the MINERAL range coatings of SGPAM are suitable for the abrasiveness and salinity of the water and slurries generally found in mines. They are classified by 3 performance grades and their marking begins with the letter M, as shown in the table below. Please, contact us for more details.
Zinc based coatings vs soils, according to EN598:
- Basic coating with pure zinc: the ductile cast iron pipes coated with a pure zinc metal layer (minimum 200 g/m²) and a layer of bituminous varnish can be buried in contact with many different types of soil, which may be identified by in-situ soil surveys except for **:
- soil with low resistivity, under 1500 Ω.cm above the water table or under 2500 Ω.cm below it
- mixed soil, i.e. comprising two or more types of soil
- soil with a pH of less than 6 and a large reserve of acidity
- soil containing waste, ash or slag, or soil contaminated by certain types of indistrial waste or effluents
- Coating with zinc and aluminium alloy
- The ductile cast iron pipes with a minimum zinc and aluminium alloy coating of 400 g/m² with a top coat can be buried in contact with most soils, except for **:
- peaty and acid soil
- soil containing waste, ash or slag, or soil contaminated by certain types of indistrial waste or effluents
- soil situated below the marine water table with a resistivity less than 500 Ω.cm
(**) in these types of soil identified by in-situ surveys, and in the event of stay currents, we recommended additional protection (such as polyethylene sleeving) or other types of suitable external coatings (see EN545, D.1, D.2.2 and D.2.3).