Tuyaux_SC_pluvial_aquacoat

PLUVIAL Aquacoat pipes DN350 to 2000 with STANDARD socket

Application
Product family
Pipes

Technical design

Tuyaux_SC_pluvial_aquacoat
350 6.000 6.0 5 378 380.9 110.5 444.5 65.951 PSB35S60BT
400 6.000 6.3 5 429 431.9 112.5 494.6 77.904 PSB40S60BT
450 6.000 6.7 5 480 483.0 115.5 546.5 92.293 PSB45S60BT
500 6.000 7.0 5 532 535.0 117.5 600.9 105.40 PSB50S60BT
600 6.000 7.7 5 635 638.1 132.5 712.0 136.90 PSB60S60BT
700 6.960 9.6 6 738 741.7 192.0 821.9 199.00 PSB70E70BT
800 6.950 10.4 6 842 845.8 197.0 935.6 243.60 PSB80E70BT
900 6.950 11.2 6 945 948.9 200.0 1043.4 291.50 PSB90E70BT
1000 6.960 12.0 6 1048 1052.0 203.0 1152.4 343.10 PSC10E70BT
1100 8.190 14.4 6 1152 1155.1 225.0 1263.7 440.00 PSC11N80BT
1200 8.190 15.3 6 1255 1260.0 235.0 1373.7 507.60 PSC12N80BT
1400 8.170 17.1 9 1462 1467.9 245.0 1592.1 678.90 PSC14N80BT
1500 8.160 18.0 9 1565 1571.1 265.0 1709.8 764.70 PSC15N80BT
1600 8.160 18.9 9 1668 1674.2 265.0 1815.9 851.30 PSC16N80BT
1800 8.150 20.7 9 1875 1881.5 275.0 2032.2 1036.30 PSC18N80BT
2000 8.130 22.5 9 2082 2088.8 290.0 2259.0 1242.22 PSC20N80BT

Features

Legend:

  • DN : nominal diameter

  • Lu : laying length, in m

  • e: thickness according to EN598 + A1 – August 2009, in mm

  • er: thickness of the cement mortar, in mm

  • ØDE : external nominal diameter of the barrel according to EN598 + A1 – August 2009, in mm

  • ØDI : internal nominal diameter of the socket, in mm

  • P : nominal depth of the socket, in mm

  • ØB : nominal diameter of the socket, in mm

  • Mass : total mass per meter (including cement coating and socket), determined with the nominal thickness, in kg/m

  • Reference : commercial reference Saint-Gobain PAM

Field of use:

  • Separate sewer system

  • Application: rising main sewerage systems and gravity flow

  • Type of effluent: rainwater

  • Perfectly watertight

  • For effluents between pH4 and pH12

  • For the soils with 6 < pH < 9

  • Majority of the soils, except the acid peaty and polluted soils

  • Resistivity of the soils:

TI_S_Schemarsistivithorszinalium_en-001_00000.jpg

Main characteristics:

  • External coating: metallic zinc 130 g/m² covered by a layer of black synthetic resin (Aquacoat).

  • Internal coating: aluminous cement mortar CALCOAT

  • Socket lining: green synthetic resin (Aquacoat).

  • Standard Gasket in Nitrile

  • EN 598 / CE Marking

  • NF Mark

  • Declaration of performances DoP-PLUVIAL005EN

  • Designed in accordance with applicable regulations:
    • NF EN 476: general stipulations regarding components used in systems
    • NF EN 752: design of sewerage projects
    • NF EN 1610: acceptance of structures

Documents