PLUVIAL Aquacoat pipes DN350 to 2000 with STANDARD socket
Technical design
| 350 | 6.000 | 6.0 | 5 | 378 | 380.9 | 110.5 | 444.5 | 65.951 | PSB35S60BT |
| 400 | 6.000 | 6.3 | 5 | 429 | 431.9 | 112.5 | 494.6 | 77.904 | PSB40S60BT |
| 450 | 6.000 | 6.7 | 5 | 480 | 483.0 | 115.5 | 546.5 | 92.293 | PSB45S60BT |
| 500 | 6.000 | 7.0 | 5 | 532 | 535.0 | 117.5 | 600.9 | 105.40 | PSB50S60BT |
| 600 | 6.000 | 7.7 | 5 | 635 | 638.1 | 132.5 | 712.0 | 136.90 | PSB60S60BT |
| 700 | 6.960 | 9.6 | 6 | 738 | 741.7 | 192.0 | 821.9 | 199.00 | PSB70E70BT |
| 800 | 6.950 | 10.4 | 6 | 842 | 845.8 | 197.0 | 935.6 | 243.60 | PSB80E70BT |
| 900 | 6.950 | 11.2 | 6 | 945 | 948.9 | 200.0 | 1043.4 | 291.50 | PSB90E70BT |
| 1000 | 6.960 | 12.0 | 6 | 1048 | 1052.0 | 203.0 | 1152.4 | 343.10 | PSC10E70BT |
| 1100 | 8.190 | 14.4 | 6 | 1152 | 1155.1 | 225.0 | 1263.7 | 440.00 | PSC11N80BT |
| 1200 | 8.190 | 15.3 | 6 | 1255 | 1260.0 | 235.0 | 1373.7 | 507.60 | PSC12N80BT |
| 1400 | 8.170 | 17.1 | 9 | 1462 | 1467.9 | 245.0 | 1592.1 | 678.90 | PSC14N80BT |
| 1500 | 8.160 | 18.0 | 9 | 1565 | 1571.1 | 265.0 | 1709.8 | 764.70 | PSC15N80BT |
| 1600 | 8.160 | 18.9 | 9 | 1668 | 1674.2 | 265.0 | 1815.9 | 851.30 | PSC16N80BT |
| 1800 | 8.150 | 20.7 | 9 | 1875 | 1881.5 | 275.0 | 2032.2 | 1036.30 | PSC18N80BT |
| 2000 | 8.130 | 22.5 | 9 | 2082 | 2088.8 | 290.0 | 2259.0 | 1242.22 | PSC20N80BT |
Features
Legend:
-
DN : nominal diameter
-
Lu : laying length, in m
-
e: thickness according to EN598 + A1 – August 2009, in mm
-
er: thickness of the cement mortar, in mm
-
ØDE : external nominal diameter of the barrel according to EN598 + A1 – August 2009, in mm
-
ØDI : internal nominal diameter of the socket, in mm
-
P : nominal depth of the socket, in mm
-
ØB : nominal diameter of the socket, in mm
-
Mass : total mass per meter (including cement coating and socket), determined with the nominal thickness, in kg/m
-
Reference : commercial reference Saint-Gobain PAM
Field of use:
-
Separate sewer system
-
Application: rising main sewerage systems and gravity flow
-
Type of effluent: rainwater
-
Perfectly watertight
-
For effluents between pH4 and pH12
-
For the soils with 6 < pH < 9
-
Majority of the soils, except the acid peaty and polluted soils
-
Resistivity of the soils:
Main characteristics:
-
External coating: metallic zinc 130 g/m² covered by a layer of black synthetic resin (Aquacoat).
-
Internal coating: aluminous cement mortar CALCOAT
-
Socket lining: green synthetic resin (Aquacoat).
-
Standard Gasket in Nitrile
-
EN 598 / CE Marking
-
NF Mark
-
Declaration of performances DoP-PLUVIAL005EN
- Designed in accordance with applicable regulations:
- NF EN 476: general stipulations regarding components used in systems
- NF EN 752: design of sewerage projects
- NF EN 1610: acceptance of structures