html_m1f33a02a
html_m2996910d
html_m1f33a02a
html_m2996910d

Purgex DN60

Product family
Pipeline protection

PURGEX DN60 protects mains DN60 up to 200. The device evacuates great air amount during the filling of the main. Allows the inlet of great air amounts (in order to avoid a vacuum effect) during the emptying of the main.

For Pipes DN60 up to 350. Evacuates small air amounts that are accumulated in the high points of the main during normal working conditions.

Technical design

html_m2996910d
60 Standard 60 Purgex 172 330 177 10 16 11 RCA60BUCH
65 Standard 60 Purgex 172 330 177 10 16 10.6 RCA65BUCH
60 Standard 60 Purgex 172 330 177 25 10.6 RCA60BUDH
65 Standard 60 Purgex 172 330 177 25 10.6 RCA65BUDH

Features

Nozzle diameter
Working pressure in bars 10 16 25
Diameter in mm 3 2.4 1.9

Connecting flange: ISO PN10/16 or ISO PN25 rotatable DN60 flange.

Other flanges available: DN65 ISO PN10/16 or ISO PN25 rotatable DN65 flange

Material and coatings

Description Material Coating
Body and bonnet Ductile Iron FGS 400/15 or 500-7 Epoxy powder: minimum 150 microns thickness
Ball float EPDM rubber encapsulated Fe P04 steel type  
Half bodies o ring Nitrile rubber  
Isolating cock Chromium coated bronze rod  
Large orifice nozzle Cu Zn 39 Pb2 bronze rod type  
Bolts Zinc coated class 8-8 steel inox A4

Performances

Nozzle air flow: cConstant Flow from 1 bar (10MCE)

PFA Ø nozzle Flow
bar mm m3/h
10 3 5
16 2,4 3,2
25 1,9 2

Air flow large orifice (for pipes DN60-200):

Main Water emptying: for DN 200 with speed 1m/s

Main Air evacuate: 180 m3/h for a depressurise 0,3 bar

Hydraulic

Small and large Orifice: external leakage

No leakage in low pressure from 0,3 bars

Marking

The marking of the valves manufactured by Saint-Gobain refers to the EN 1074-2 and EN 19 international standards.

Markings are either integral markings, cast in the body, or markings made on plates, securely fixed to the body, in accordance with the EN 19 standard specifications.

EN 19 Specifications Saint-Gobain valves process
Table 1 – Valve markings Requirements
1 DN

EN 19 § 4.2.1

Mandatory markings

Shall be integral markings or on a marking plate

Integral
2 PN Integral
3 Material Integral
4 Manufacturer's name or trademark Plate
11 Reference to Standard

EN 19 § 4.3

Supplementary markings

Items 7 to 21 in Table 1 are optional

Plate
12 Melt identification Integral
16 Quality test Printed on body
18 Manufacturing date Plate
21 Closing direction Plate + sticker on body
Purgeur_60_triple_fonction_marquage

Air evacuate operating

Purgeur_60_triple_fonction_fonctionnement

Installation

Purgeur_60_triple_fonction_installation
Mounting on tee: cock isolating allows, without water cut of sector, the regular maintenance of Purgex in particular change of the floats ball
Purgeur_60_triple_fonction_installation
Mounting with reduction flange

Spare parts references

Description Reference
Modulating Small orifice nozzle 162302
O’ ring body/bonnet 162516
Ball float Ø 125 162484
Purgeur_60_triple_fonction_tuyere
Purgeur_60_triple_fonction_joint
Purgeur_60_triple_fonction_flotteur