Upstream Pressure Support Hydrovalve with remote Electric Control - E3116-31 - E4116-31
AUTOMATIC CONTROL VALVES

Upstream Pressure Support Hydrovalve with remote Electric Control - E3116-31 / E4116-31

Product family
Pipeline protection

The automatic valve supports the upstream pressure regardless of flow rate variations; the calibration value is adjustable.

With the aid of a solenoid valve, it is also possible to open or close by means of a control unit or remote impulses.

If the upstream pressure should fall below the calibration value, the valve will move to the fully closed position, ensuring operation even in static conditions.

Flange drilling according to EN 1092/2, different on request.

Certification and testing according to EN 1074.

Technical design

E3116-31 80 10 16 31 E36A8016P31
E3116-31 100 10 16 36 E36B1016P31
E3116-31 125 10 16 51 E36B1216P31
E3116-31 150 10 16 58 E36B1516P31
E3116-31 200 10 102 E36B2010P31
E3116-31 200 16 102 E36B2016P31
E3116-31 250 10 176 E36B2510P31
E3116-31 250 16 176 E36B2516P31
E3116-31 300 10 293 E36B3010P31
E3116-31 300 16 293 E36B3016P31
E3116-31 400 10 500 E36B4010P31
E3116-31 400 16 500 E36B4016P31
E3116-31 500 10 862 E36B5010P31
E3116-31 500 16 862 E36B5016P31
E3116-31 600 10 1002 E36B6010P31
E3116-31 600 16 1002 E36B6016P31
E4116-31 40/50 10 16 25 E46A5016P31
E4116-31 65 10 16 25 E46A6516P31
E4116-31 80 10 16 30 E46A8016P31
E4116-31 100 10 16 43 E46B1016P31
E4116-31 150 10 16 89 E46B1516P31
E4116-31 200 10 142 E46B2010P31
E4116-31 200 16 142 E46B2016P31
E4116-31 250 10 253 E46B2510P31
E4116-31 250 16 253 E46B2516P31
E4116-31 300 10 425 E46B3010P31
E4116-31 300 16 425 E46B3016P31
E4116-31 400 10 784 E46B4010P31
E4116-31 400 16 784 E46B4016P31
E4116-31 600 10 2250 E46B6010P31
E4116-31 600 16 2250 E46B6016P31

Features

Applications

  • On the supply lines of the tanks to regulate, connected to an electronic float probe, flow rate and level.
  • In gravity pipelines to ensure supply to users located in the highest areas together with the possibility of closing and opening in response to control or alarm signals.

Accessories

  • Open-close indicator.
  • Manometers.
  • Self-cleaning high capacity filter.
  • Limiter of opening manual

Directions for use

  • Inlet and outlet pressure, flow rate and application are required for cavitation sizing and analysis.
  • In the support function a distance of 3 diameters upstream of the valve is recommended for best operation

Optional configurations

  • Upstream pressure sustaining valve with solenoid control valve and anti-backflow system.
  • Upstream pressure relief valve with quick-acting solenoid and pilot control valve.
  • Upstream pressure sustaining valve with high sensitivity solenoid and pilot control valve.

Operating conditions

  • Fluid: treated water.
  • Minimum pressure: 0,7 bar.
  • Maximum pressure: 16 bar. Higher on request.
  • Maximum temperature: 70 °C.

Solenoid valve data

  • Voltage: 24V DC, 24V/50Hz, 230V/50Hz. Other voltage on request.
  • Electrical consumption: inrush AC (VA) 24, hold AC (VA) 17 (8 W), DC hot/ cold coil 8/9 W.

How it works

The automatic valve is controlled by an adjustable two-way pilot (5) which receives, through the regulation unit (4), the upstream pressure value.

When the latter rises above the set-point, the pilot (5) opens; the pressure in the valve chamber (10) consequently decreases, causing the shutter (11) to rise.

When the pressure is lower than the set value, the pilot reduces the degree of opening by modulating; the pressure in the chamber (10) increases and the shutter (11) descends towards the seat (12), reducing or interrupting the flow through the main valve.

Furthermore, a solenoid (14), which acts on a two-way auxiliary valve (13), interrupts the flow of the circuit, causing the main valve to close in response to remote impulses. Upon request, it is also possible to force the total opening of the hydrovalve.

Upstream Pressure Support Hydrovalve with remote Electric Control - E3116-31 - E4116-31-functioning

Installation diagram

In the installation diagram of the valve, connected to an electronic control unit (7) which sends pulses to the circuit solenoid, shut-off devices (1, 2) and bypass allow maintenance,

And a filter (3) holds back possible impurity. There valve Of support to action live (4), reliable even after long periods of inactivity, represents the best solution for the bypass. The insertion of anti-water hammer vents (5, 6) upstream and downstream is also recommended.

Upstream Pressure Support Hydrovalve with remote Electric Control - E3116-31 - E4116-31-installation