DIREXIONAL ZMU pipes DN100 to 300 with UNIVERSAL TYTON socket + Weld bead Ve
Technical design
| 100 | 5.970 | C100 | 6.1 | 5.0 | 118 | 120.5 | 140 | 188 | 90 | 22.300 | 224302 |
| 125 | 5.970 | C64 | 6.1 | 5.0 | 144 | 146.5 | 140 | 215 | 95 | 28.600 | 224303 |
| 150 | 5.970 | C64 | 6.2 | 5.0 | 170 | 172.5 | 148 | 230 | 95 | 34.400 | 224305 |
| 200 | 5.970 | C64 | 6.5 | 5.0 | 222 | 224.5 | 155 | 290 | 100 | 47.000 | 224307 |
| 250 | 5.970 | C50 | 6.8 | 5.0 | 274 | 276.5 | 166 | 350 | 110 | 60.900 | 224308 |
| 300 | 5.970 | C50 | 7.4 | 5.0 | 326 | 328.5 | 180 | 408 | 115 | 77.600 | 224309 |
Features
Legend
-
DN: nominal diameter
-
Lu: laying length, in m
-
Class: pressure class according to EN 545 and ISO 2531
-
e: nominal thickness according to ISO 2531, in mm
-
e1: external thickness of ZMU coating, in mm (cement mortar with acrylic fibers and resin) according to EN15542
-
ØDE: external nominal diameter of the barrel according to EN 545 and ISO 2531, in mm
-
ØDI: internal nominal diameter of the socket, in mm
-
P: nominal depth of the socket, in mm
-
ØB: nominal diameter of the socket, in mm
-
c: weld bead position, in mm
-
Mass: total mass per meter (including cement coating and socket), determined with the nominal thickness, in kg/m
-
Reference: commercial reference Saint-Gobain PAM
Field of use:
-
For drinking water networks
-
High durability
-
Total compatibility with drinking water
-
For most of the soils, including rocky soils, those pipes can be laid with the native soils backfill.
-
Resistivity of the soils > 250 Ohm.cm
-
Joint protection with elastomer sleeve and HDD metal cone
-
Adapted to the trenchless pipe laying in rocky soils (horizontal directional drilling and pipe bursting)
Main characteristics:
-
Elastomer quality: EPDM
-
External coating: a layer of zinc-aluminium 85/15 alloy, enriched with copper, with a minimum surface density of 400g/m², applied by spraying molten metal onto the surface of the iron, using an electric arc spray gun, from ZnAl (Cu) alloy wire + a protective layer of Aquacoat (semi-permeable), a water-based blue acrylic of average thickness 80 microns applied using a spray gun + cement mortar ZMU with polymeric additiv and reinforced with PE fibers
-
Internal coating in cement mortar CHF (thickness 5mm)
-
ZMU pipes in accordance with EN 545
-
ZMU coating according to EN 15542
Type of water:
Ductile iron pipes with internal coating of sulphate resisting blast furnace cement mortar are adapted to convey all types of drinking water in conformity with Directive EU 2020/2184.
In case of other type of water, please refer to below information:
|
Minimum value |
Maximum value |
||||
|---|---|---|---|---|---|
|
Parameter |
pH |
CO2 aggressive |
Sulphate |
Magnesium |
Ammonium |
|
Unit |
- |
mg/l |
mg/l |
mg/l |
mg/l |
|
Value |
5,5 |
15 |
3000 |
500 |
30 |
Blast furnace cement mortar is a sulphate resisting cement (SRC).