150 6.000 5.0 4.0 2.0 170 173.4 100.5 222.0 24.800 40 TSB15S60BG
200 6.000 5.1 4.0 2.0 222 225.2 106.5 279.0 33.300 40 TSB20S60BG
250 6.000 5.3 4.0 2.0 274 276.8 105.5 334.0 42.600 38 TSB25S60BG
300 6.000 5.6 4.0 2.2 326 328.8 107.5 392.0 53.300 35 TSB30S60BG
350 6.000 6.0 5.0 2.2 378 380.9 110.5 446.0 69.300 32 TSB35S60BG
400 6.000 6.3 5.0 2.2 429 431.9 112.5 499.5 81.300 30 TSB40S60BG
450 6.000 6.7 5.0 2.2 480 483.0 115.5 554.0 95.700 29 TSB45S60BG
500 6.000 7.0 5.0 2.5 532 535.0 117.5 608.6 111.400 28 TSB50S60BG
600 6.000 7.7 5.0 2.5 635 638.0 132.5 718.0 141.800 26 TSB60S60BG
700 6.960 9.6 6.0 2.5 738 741.7 192.0 830.0 211.03 29 TSB70E70BG
800 6.950 10.4 6.0 3.0 842 845.8 197.0 935.6 258.74 28 TSB80E70BG
900 6.950 11.2 6.0 3.0 945 948.9 200.0 1043.4 308.61 27 TSB90E70BG
1000 6.960 12.0 6.0 3.0 1048 1052.0 203.0 1152.4 362.5 26 TSC10E70BG

Features

Legend:

  • DN : nominal diameter

  • Lu : laying length, in m

  • e: thickness according to EN598 + A1 – August 2009, in mm

  • e1: according to EN14626, in mm

  • er: thickness of the cement mortar, in mm

  • ØDE : external nominal diameter of the barrel according to EN598 + A1 – August 2009, in mm

  • ØDI : internal nominal diameter of the socket, in mm

  • P : nominal depth of the socket, in mm

  • ØB : nominal diameter of the socket, in mm

  • Mass : total mass per meter (including cement coating and socket), determined with the nominal thickness, in kg/m

  • Reference : commercial reference Saint-Gobain PAM

Field of use:

  • Separate sewer system and combined sewer system

  • Application: gravity flow and rising main sewerage systems

  • Type of effluent: domestic wastewater and rainwater

  • Perfectly watertight

  • For effluents between pH4 and pH12

  • Extremely corrosive soils ; storage in warm countries is not recommended

  • Resistivity of the soils: see drawing

TI_S_SchemarsistivitPUX_en-001_00000.jpg

Main characteristics:

  • External coating BioZinalium: a layer of zinc-aluminium alloy enriched with copper Zn85Al15 (Cu), with surface density of 400 g/m² covered with a protective red (RAL 3011) layer AQUACOAT 80 μm (mini average), without VOC and without BPA polyethylene according to NF EN 14628-2006 (DN80 to 500: extrusion method by tubing – DN500 to 700: extrusion method by wrapping)

  • Internal lining: aluminous cement mortar CALCOAT

  • Socket coating: zinc rich paint 40 μm or zinc-aluminium 200 g/m² + red AQUACOAT 160 μm (mini average)

  • Spigot coating: zinc-aluminium (Cu) 400 g/m² + red AQUACOAT 160 μm (mini average)

  • Standard Gasket in Nitrile

  • EN 598 / CE Marking

  • Declaration of performances DoP-INTEGRAL005EN

  • Designed in accordance with applicable regulations:
    • NF EN 476: general stipulations regarding components used in systems
    • NF EN 752: design of sewerage projects
    • NF EN 1610: acceptance of structures

Documents