Natural Standard Surejoint TT PE Pipe

TT PE pipes with notches (CONTROL+) DN150 to 600 with STANDARD gasket (prefered pressure classes)

Application
Product family
Pipes

Technical design

Natural Standard Surejoint TT PE Pipe
150 6 C40 4.5 2 170 173.4 100.5 222 23 SSB15Q60AGV
200 6 C40 4.7 2 222 225.2 106.5 279 31.4 SSB20Q60AGV
250 6 C40 5.5 2 274 276.8 105.5 334 43.8 SSB25Q60AGV
300 6 C40 6.2 2.2 326 328.8 107.5 392 57.4 SSB30F60AGV
350 6 C30 6.4 2.2 378 380.9 110.5 446 72.5 SSB35G60AGV
400 6 C30 6.5 2.2 429 431.9 112.5 494.6 83.5 SSB40G60AGV
450 6 C30 6.9 2.2 480 483 115.5 554 97.8 SSB45G60AGV
500 6 C30 7.5 2.5 532 535 117.5 608.6 117.1 SSB50G60AGV
600 6 C30 8.7 2.5 635 638.1 132.5 718 155.4 SSB60G60AGV

Features

Legend:

  • DN: nominal diameter

  • Lu: laying length, in m

  • Class: pressure class according to EN 545 and ISO 2531

  • e: nominal thickness according to ISO 2531, in mm

  • e1: thickness of polyethylene according to EN 14628-1

  • ØDE: external nominal diameter of the barrel according to EN 545 and ISO 2531, in mm

  • ØDI: internal nominal diameter of the socket, in mm

  • P: nominal depth of the socket, in mm

  • ØB: nominal diameter of the socket, in mm

  • Mass: total mass per metre (including cement coating and socket), determined with the nominal thickness, in kg/m

  • Reference: commercial reference Saint-Gobain PAM

  • Marking sticker can be different depending on DN

Field of use:

  • Soils characteristics:

    Ductile iron pipes coated with TT PE may be buried in contact with a large number of soils, normal and highly corrosive soils (low resistivity soil, mixed soils, polluted soils...), also in soils with occurrence of stray currents. Please refer to the informative annex D of EN545.

  • Water characteristics:

    Ductile iron pipelines supplied with lining sulfate resisting blast furnace cement mortar may be used to convey all types of water intended for human consumption in conformity with the Directive 98/83/EC.

    For other types of water, the limits of use are as given in below Table. Please refer to the informative annex E of EN545.

     

    Minimum value

    Maximum value

         

    Parameter

    pH

    CO2 aggressive

    Sulphate

    Magnesium

    Ammonium

    Unit

    -

    mg/l

    mg/l

    mg/l

    mg/l

    Value

    5,5

    15

    3000

    500

    30

Main characteristics:

  • Pressure class in conformity with Standard EN 545-2010 and ISO 2531-2009
  • External coating with 2 barriers, in accordance with EN14628-1:2020 (option PE-G):
    • Back barrier: a metallic layer of ZnAl(Cu) 85/15 alloy (mini surface density 400 g/m²) applied by spraying molten metal on to the surface of the ductile iron + finishing acrylic layer (Aquacoat)
    • Front barrier: a continuous thick organic layer of extruded PE + hot melt adhesive layer applied on the back barrier, standard thickness according to DN (table 2 of EN14628-1)
  • Internal coating: sulfate resisting blast furnace cement mortar
  • Standard joint SUREJOINT in alimentary elastomer EPDM (ACS, KTW, WRAS,…)
  • Restraining possible with STD Vi joint (without bolts)

Fitting a SUREJOINT gasket

When installing the SUREJOINT STARDARD Gasket:

  • Bend manually the joint to form a hart, having the connecting nozzle opposite of your hands.
  • Begin the gasket positioning in the socket groove by introducing the nozzle in a notch of the pipe front face.
  • Choose one notch on the upper section of pipe, in order that the nozzle remains accessible when in the trench.
  • Continue the joint installation as usual with Standard one.
User guide - Standard Gasket CONTROL+ Testing Device
TI_W_MiseenoeuvreControl-Surejoint_00000.jpg

SUREJOINT quality check

The use of SUREJOINT Standard gasket, with the SUREJOINT Natural pipe, gives an immediate opportunity to check the integrity of the joint during installation. The check can detect any major defects during the jointing of the pipe, allowing any remedial work to be carried out straight away.


Checking of the joint is made by using the SUREJOINT testing device.


For full instructions of how to use SUREJOINT please refer to the Installation manual.

Documents